Company Profile
-
Company Profile
PERTAMINA is a State Owned oil & gas company (National Oil Company), established on December 10, 1957 under the name PT PERMINA. In 1961 the company changed its name to PN PERMINA and after the merger with PN PERTAMIN in 1968 it became PN PERTAMINA. With the enactment of Law 8 of 1971 the company became PERTAMINA. This name persisted until after PERTAMINA changed its legal status to PT PERTAMINA (PERSERO) on October 9, 2003.
-
Corporate Commitment
-
Our Networks
Provides information of PERTAMINA
- Career Development
Opportunities within Pertamina are extremely wide because we operate such a diverse set of businesses: Exploration & Production, Refining, Distribution to Marketing of products, and geothermal.
-
Company Profile
- Our Business
-
Our Business
PERTAMINA in conducting business activities in the field of energy and petrochemicals, was divided into two sectors, namely upstream and downstream, and supported by the activities of Children's Subsidiaries and Joint Ventures
-
Upstream
The business activities of the Pertamina Upstream Directorate cover exploration, production, and transmission of oil and gas. Other activities are Coal Bed Methane (CBM) and geothermal operations.
-
Downstream
Pertamina Downstream activities comprises of:
- Our Products
- Industry Marine
- Announcements
-
Our Business
- News Room
- Investor Relations
- Social Responsibility
- HSSE
Liquified Petroleum Gas
Description
LPG is the light gaseous product which is yielded from the petroleum distillation or also yielded from the natural gas condensation in Processing Unit Plant. LPG used as fuel for the household and the industry. LPG is especially used by middle level society which its requirement progressively mount from year to year because it's environment friendly.
Application
In the industrial area, the LPG product used as substitution of Freon, Aerosol, Refrigerant/ Cooling Agent, cosmetic and also used as special product raw material.
Specification
According to its use, LPG is differentiated to :
- LPG Mix
- LPG Propane
- LPG Butane
LPG Mix is the mixture of Propane and Butane with composition among 50 % and 50 % of volume and added by odorant (Mercaptant) and generally used for the fuel in household.
LPG Propane and LPG Butane are LPG which is containing Propane 95 % and Butane 97,5 % of volume each and added by odorant (Mercaptant), generally used for industry.
LP Mix specification
| Min | Max | Methode | ||||||||||||||
| Spesilic Gravity at 60/60 °F | to be reported |
to be reported | ASTM D-1657 | |||||||||||||
| Vapour Pressure 100 °F, psig | - | 120 | ASTM D-1267 | |||||||||||||
| Weothering Test 36 °E,%vol | 95 | - | ASTM D-1837 | |||||||||||||
| Copper Corrosion. thr, 100 °F | - | ASTM No. 1 | ASTM D 1838 | |||||||||||||
| Total Sulfur. gr/100 cuft | - | 15 | ASTM D-784 | |||||||||||||
| Water Content | No Free Water |
No Free Water | Visual | |||||||||||||
| Composition: | ASTM D-2163 | |||||||||||||||
| • C1 % vol | 0.2 | |||||||||||||||
| • C3 & C4 % vol | 97.5 | |||||||||||||||
| • C5 & heavier % vol | 2.0 |
|||||||||||||||
| Ethyl or Buihyl. ml/1000 AG | 50 | 50 |
||||||||||||||
| Mercaptan Added | ||||||||||||||||
LP Propane specification
| Min | Max | Methode | ||||||||||||||
| Spesilic Gravity at 60/60 °F | to be reported | ASIM D-1657 | ||||||||||||||
| Vapour Pressure 100 °F, psig | - | 210 | ASTM D-1267 | |||||||||||||
| Weothering Test 36 °E,%vol | 95 | - | ASTM D-1837 | |||||||||||||
| Copper Corrosion. thr, 100 °F | - | ASTM No. 1 | ASTM D 1838 | |||||||||||||
| Total Sulfur. gr/100 cuft | - | 15 | ASTM D-784 | |||||||||||||
| Water Content | No Free Water | Visual | ||||||||||||||
| Composition: | ASTM D-2163 | |||||||||||||||
| • C3 Total % vol | 95 | |||||||||||||||
| • C4 & heavier % vol | 2.5 | |||||||||||||||
| Ethyl or Buihyl. ml/1000 AG | 50 | |||||||||||||||
| Mercaptan Added | ||||||||||||||||
LP Butane specification
| Min | Max | Methode | ||||||||||||||
| Spesilic Gravity at 60/60 °F | to be reported | ASIM D-1657 | ||||||||||||||
| Vapour Pressure 100 °F, psig | - | 70 | ASTM D-1267 | |||||||||||||
| Weothering Test 36 °E,%vol | 95 | - | ASTM D-1837 | |||||||||||||
| Copper Corrosion. thr, 100 °F | - | ASTM No. 1 | ASTM D 1838 | |||||||||||||
| Total Sulfur. gr/100 cuft | - | 15 | ASTM D-784 | |||||||||||||
| Water Content | No Free Water | Visual | ||||||||||||||
| Composition: | ASTM D-2163 | |||||||||||||||
| • C4 % vol | 97.5 | |||||||||||||||
| • C5 % vol | 2.5 | |||||||||||||||
| • C6 & heavier % vol | Nil | |||||||||||||||
| Ethyl or Buihyl. ml/1000 AG | 50 | |||||||||||||||
| Mercaptan Added | ||||||||||||||||